will be saved for more infos
 request infos

Hot-runner-multizone-temperature-controller
Production line NL 5000 with additional option:
diagnostic routines for tool control


Extensive tool analyzing routines tells how the tool is operating.
 
  • if sensor corresponds to heater
  • detecting of voltage reversal of sensors
  • sensor destruction
  • load breakdown

 

In addition to the control functions explained for the NL5000 already, this
device is extended by diagnostic routines for controlling the controlled tool.

If the diagnostic modus is on, the controller checks if the tool is connected correctly:
It checks the following subjects:
- if sensor corresponds to the right heater
- detecting of voltage reversal of sensors
- sensor breakage
- load breakdown

Before checking the tool with the diagnostic routines, it must be checked that no load exit is connected to a sensor and the other way around.




During the diagnostic process all heating zones (one after an other) will get an additional surplus of power. The controller checks the reaction time interval of the sensor and if the correct sensor ist reacting, or if a different sensor is reacting to the power surplus.




At the end of the test the controller informs, if the tool was connected correctly ("good" or "bad").
It will be displayed, which tool is checked by which sensor.