How to useThe design is optimized especially for use in tool temperature controlling and in the plastic industry.
It offers the best overview for all control zones, it is simple to use and includes
extensive self control processes.
The controller is usable in multizone-basic-units for hot-runner-, presses- and extruders-applications
ConstructionCompact electronic control unit with integrated Triac-Switch (load-switch) constructed
as a 19" blade (3HE/10TE, plug is compatible with other control
blades 3060TMD and 3080TPS, to use in basic units
RG225 ... RG3060 (2... 30 zones).
Function
Control
Microprocessor controller with optimised automatic self tuning for an optimized adaption to the controlled-system.
To use on reactive nozzel heaters as well, as on slow reacting controller processes and extruder zones
Current-Temperature-Display
LED-Display (3 element fields) shows temperature in normal processing.
Additional the 10-element-bargraph shows the variance to control input
with a logarithmic scaling in 3 colors |
|
Control-Input Menue
Using UP/DOWN Buttons the dispay automatically switch to the
control input display. Switch back can be done automatically or
manually.
High/ Low temperature
High/ Low temperature-control input values can be set with the
MODE-Button. The range is between +/-3 ... 99K. Values will be
displayed.
Getting out of range will be anounced by blinking of a red LED.
At the same time the signal relais will be conected.
Cooler Exit (Option)For controlling extruder-applications, a version with cooler exit can be delivered.
It can directly control smal fans (-motors)
Automatic detection of destructed controllers
Destructed detectors will be anounced by a corresponding LED light.
At the same time the controller will use the last control input for setting
the controller to manual power control Manually settings are possible at any time.
Manually setting of the control input
The control input can be set manually at any time
Power control
The corresponding LED shows that the, 60%-zoning was activated.
The controller works then with a maximum of 60% power-output, to go easy on sensitive heaters. |
|
SoftstartThe controller always starts with a soft start period for sensitive starting of
cold heaters.The period is variable.
The temperature will stay below 80°C in this period.
Boost-FunctionThe 3070 THD-14 controller offers the possiblity to set the control input 1-9K
higher then it is normally set to.
This can be done at the first heating process to shorten the time to free froozen
channels.
After the boost the controller set himself back to control input.
This controlled high setting of temperature, frees frozen channels much faster.
Second control input
In addition with the Signal/ Alarm-Blade NL 3053 SX it is possible
to activate a standby-routine. This will force a decline of the
temperature to the defined standby input (in % ot the control input).
Power surveillance
Permanent voltage display with a 10-Element-Bargraph.
The presize heating power (load-current) can be shown on a display. Additional a blinking LED will show if a loading burst did happen (load breakdown).
More self control functionsControl unit voltage reversal (wrong polarity) and Triac-Error will be extensively explained in our instruction manual.
Safeguarding in case of wrong sensor-polarity and Triac-error. |