NL 2006

Controller with integrated Load-Switch 230V/10A
Additional power control 230V/3A
Digital display of nominal value and current value
Microprocessor controlled
Security alarm shutdown   

 

How to use

This handy device was developed especially for the plastic industry.
They are very usefull for controlling single nozzles - also with reactive characteristic -, for additional heaters and last but not least for other small applications.

The temperature controller NL 2006 is an oeconomic opportunity to  control heater-systems up to 2,3 kW accuratly.

It ist also possible to set the power control for load currents up to 690 W, if the load current does not need a controlled-system

Construction

Ready to plug-in consolidated controller for single installation.
Cable with three pin plug.


Manual power control

It is still possible to switch to manual power control, even if a sensor is connected.



Function

Control

Good disturbance value control makes a stable temperature control possible.
(stetig proportionale Verhalten des Reglers mit PID-Charakteristik)
In all controlled systems it is important to have an optimal sensor positioning
 

Temperature display

LED-Display shows temperature in normal processing.
The top area shows the current temperature, the bottom area the set-value.
By pressing a button it is possible to change the shown topics to show other parameters.
Options:
manual power control in case of  destructed sensor
manual power control for separate power load


Set value input

Using the UP/DOWN Buttons the dispay automatically switch to the control input display.  Switch back can be done automatically or manually.


Separate power load

With the controller type NL 2006 it is additionally posssible  to  control a heater system. It can  dimm a heater (wattage up tp 690 W).

 

Softstart

The control of the start process depends on the temperature.
Is the start temperature of the tool higher then 60 °C, the device directly starts, because it will  assume that the tool has already warmed up.
In case off cold tools (<60°C) the power control will be set automatically to 50% for a time period of 4 minutes.
This makes sure that cold heaters get a sensitive start and hot heaters donīt waist time with a soft start period.


Exceeding the temperature limit

Does the current temperature exceeds the  control-input by more then  10K a safty shutdown will cut off power supply to the heater.
A red signal LED will will anounce the event.


Automatic detection of destructed sensors

Destructed sensors will be anounced by a corresponding sign on the display.
At the same time the controller will use the last control input for setting
the controller to manual power control.
Manually settings are possible at any time.



Sensor connection check

Sensor voltage reversal will be checked and will cause a shutdown of the security relais.